Home Product Kinco VFD KC100 Series Inverter KC100-2S-0R40G KC100-2S-0R75G KC100-2S-01R5G KC100-4T-0R75G KC100-4T-01R5G KC100-4T-02R2G
Kinco VFD KC100 Series Inverter KC100-2S-0R40G KC100-2S-0R75G KC100-2S-01R5G KC100-4T-0R75G KC100-4T-01R5G KC100-4T-02R2G
USD
$77
.98
Item Description
● Product Name : KC100 Series Inverter

● Feature : 
(1) Only 65mm wide, easy of installation;
(2) European crimping terminal, IO terminals without tightening screws, can improve install efficiency by 30%;
(3) Support network port connected to external keyboard and use standard MODBUS communication protocol and scheme;
(4) Various frequency given channel selections such as panel, analog, communication, pulse, PID, multi-speed, etc.
(5) Built-in AVR, over-modulation, instantaneous non-stop and other functional
● Detail :
(1) Voltage: Single-phase 220V/0.4-2.2kW and Three-phase 380V/0.75-5.5kW
(2) Communication: Modbus RS485
(3) Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point;
(4) Overvoltage suppression protection: When no brake resistor is connected, the operating frequency is automatically adjusted or the bus voltage rise is suppressed by flux braking.
(5) Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping;
(6) Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown;
(7) Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise;
(8) Overvoltage, overcurrent fault protection;
(9) Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it;;
(10) Output phase loss: Output phase loss fault can be quickly detected before and during operation;
(11) Phase to phase short circuit and short circuit to ground fault: quickly detected within 20ms before operation;
(12) Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc.
(13) Industry applications
HVAC, sewage treatment, manufacturing production lines, fan ventilation systems, logistics and transportation, air conditioner cooling systems, woodworking machinery, and various automated production equipment and other industries.
● Related file download URL :




WhatsApp